VA series is a high performance AC drive for machine tool spindles. It is compatible with synchronous and asynchronous motor. VA series support RS485 communication and EtherCAT bus, and combine with the upper computer to have multiple servo drives controlled with networking and field bus system.
Sample provide:
YESSample freight payer:
BuyerTerm of payment:
T/T, L/C, D/PCustomized:
YESWarranty:
18 MonthsDelivery Time:
5-7 Working Days For Standard Series; 7-14 Working Days For Customized AC DrivesTransportation:
Express · Sea Freight · Land Freight · Air FreightPackage:
Standard Export Package Carton/WoodAvailability:
OEM/ODM, Minmum Order RequestPlace of Origin:
ChinaShipping Port:
ShenzhenCertification:
CE, EAC, ISO9001, OHSAS18001, TS16949, SGProduct Overview
Item | Description |
Product Name | Frequency Inverter/ AC Drive |
Model Number | VA-H-4TxxG |
Power Range | 3.7kW-160kW |
Rated Input Voltage | 3 phase 380V/480V |
Rated Output Voltage | 3 phase 0 to rated input voltage |
Input Frequency | 50Hz/60Hz |
Applicable Motor | Asynchronous Motor, Synchronous Motor |
Control Mode | V/F Control, Vector Control, Sensorless Vector Control, Sensor Vector Control |
Communication | Modbus 485 RTU, EtherCAT |
IP Class | Standard IP20 |
Overload Capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Model Explanation
Product Catalogue
VA−H−4TXXG
Power(kW) | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | |
Motor Power(kW) | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | |
Output | Voltage(V) | 3 phase 0~Rated Voltage | |||||||||||||||
Rated Current(A) | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | 176 | 210 | 253 | 304 | |
Max Current(A) | 16 | 23 | 31 | 43 | 54 | 70 | 81 | 108 | 135 | 164 | 202 | 270 | 317 | 378 | 400 | 547 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag ;feature) | ||||||||||||||||
Input | Voltage/ frequency | 3 Phase 380V~480V;50Hz/60Hz | |||||||||||||||
Allowable voltage range | 323V~528V;Voltage imbalance :≤3% ;allowable frequency fluctuation:±5% | ||||||||||||||||
Rated Current(A) | 10 | 15 | 19 | 26 | 33 | 43 | 50 | 66 | 83 | 100 | 123 | 165 | 160* | 196* | 232* | 282* | |
Braking unit | Built-in as standard | Built-in as optional | |||||||||||||||
IP | IP20 | ||||||||||||||||
Cooling mode | Natural air cooling | Forced air cooling |
Technical Specification
Control Characteristics |
Control mode |
synchronous motor control without encoder ;asynchronous motor control without encoder |
synchronous motor control with an encoder/asynchronous motor control with an encoder |
|
Startup torque |
0.2% rated speed on motor,180% rated torque |
0 speed,180% rated torque |
||
Range of speed regulation |
1:200 |
1:1000 |
||
Precision of steady speed |
± 0.5% |
± 0.02% |
||
Product Functions |
Key functions |
undervoltage regulation, speed tracking, torque limitation, multi-stage speed, motor self-learning, weak magnetic control, current limitation. |
||
Designated speed mode |
RS485, keyboard, terminal, analog quantity, multi-stage speed, simple PLC, PID, pulse frequency. |
|||
Braking capacity on Power Consumption |
400V Drive:brake unit voltage:650~750V。 |
|||
Dual 485 communication ports |
Dual 485 communication interface supports Modbus protocol(RTU);standard operation panel meet remote control , up to 500 meters. |
|||
Common DC bus |
The whole series meet common DC bus power supply for multiple drives. |
|||
Independent air duct |
The whole series uses independent air duct design,and support radiator cabinet with installed outdoors |
|||
Protection Function |
undervoltage, overcurrent protection, over-voltage protection, abnormal comparison level, self-learning to identify fault, protection of the module, radiator overheating protection, overload protection on Drive, overload protection on motor, peripheral protection, current detection, the output of a short circuit, abnormal operation of the power,abnormal input power, EEPROM anomaly, relay and abnormal disconnection, analog input, temperature sampling disconnection, encoder, an abnormal motor overheating (PTC), communications, hardware, overload protection. |
|||
Efficiency |
Rated power: 7.5kW and lower power grade≥93%;11kW to 15kW≥95%。 |
|||
Environment |
Operating site |
The product should be mounted vertically in the electric control cabinet with good ventilation.Horizontal or other installation modes are not allowed.it is air cooling |
||
Ambient temperature |
-10 to +40℃, the product must be de-rated output current for the ambient temperature between 40℃ ;to 50℃, the rated output current must be de-rated for 1% per 1℃ ;temperature rise |
|||
Humidity |
5~95%,no condensing |
|||
Altitude |
0~2000m, the product must be de-rated rated output current for the altitude above 1000 meters, the rated output current must be de-rated for 1% per 100 meters rise |
|||
Vibration |
3.5 m/s2,2~9Hz;10 m/s2,9~200Hz;15 m/s2,200~500Hz。 |
|||
Storage temperature |
−40~+70℃。 |
AC Drive for Machine Tool Spindles Motor Wiring
Short circuit or grounding of the EtherCAT VFD output terminals is prohibited. Otherwise, it will cause damage to the internal components of the drive.
Avoid output cables (U/V/W) short circuit or short circuit to enclosure, otherwise there is a risk of electric shock.
It is strictly forbidden to connect a capacitor or phase lead LC/RC noise filter to the output of the Positioning Control Inverter, otherwise the drive will be damaged.
When a contactor is installed between the drive and the motor, the switching action of the output contactor cannot be performed during the operation of the drive, otherwise a large current will flow into the drive to and the drive will report fault information.
Cable length between drive and motor: When the cable between the RS485 Communication VFD and the motor is too long, the high-order harmonic leakage current at the output will adversely affect the drive and peripheral devices. It is recommended to install a output AC reactor when the motor cable exceeds 100 meters, and contact the manufacturer to inquire whether the carrier frequency needs to be modified.
Installation Dimension
VA−H−4T7.5G and below power class VA−H−4T11G and above power class
Voltage
Model
Appearance, Installation Dimensions(mm)
weight(kg)
W
H
D
W1
H1
D1
T1
Hole d
400V
VA−H−4T3.7G
155
249
197.7
136
232
69
8
5.5
3.3
VA−H−4T5.5G
VA−H−4T7.5G
VA−H−4T11G
210
337
230
150
324
107.5
2.5
7
8.5
VA−H−4T15G
VA−H−4T18.5G
285
440
250
200
425
107.5
2.5
7
17
VA−H−4T22G
VA−H−4T30G
VA−H−4T37G
315
575
247
220
553
123.5
2.5
10
25
VA−H−4T45G
VA−H−4T55G
400
615
275
270
590
123.5
3.0
10
35
VA−H−4T75G
VA−H−4T90G
465
745
335
343
715
156
3.0
12
55
VA−H−4T110G
VA−H−4T132G
540
890
395
370
855
205.5
4.0
14
85
VA−H−4T160G
Applications
|
|
|
|
|
|
|
|
High Frequency Speed VFD Representative Industry
As an advanced China Automation & Control Systems Provider,The use of V&T frequency drive (VFDs): a VFD is used to regulate the speed and torque of the Motor according to the variation of the load in order to improve the Motor energy efficiency. The High Performance Universal Inverter of Shenzhen V&T Technologies Co.,Ltd. is suitable for CNC Drives Inverter, Grinder, Printing Packaging, Petrochemical, Textile, Cable Machinery, Food Packaging, Electric Vehicles, Plastic Machinery, Metal Products Equipment, Centrifuges, Universal fields and High-end applications ,High accuracy and speed application requiring closed-loop vector or torque control.
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Categories
Copyright © 2024 Shenzhen V&T Technologies Co.,Ltd.. All Rights Reserved. Power by
IPv6 network supported