V9-R is a special-purposed drive control unit for Heat Pump Water Heater with V/F vector control functions. It devotes to controlling water-source heat pump and air-source heat pump systems. It not only achieves requirements of cost saving, improvement on product quality and production efficiency,but also easy maintenance and easy commissioning.
Sample provide:
YESSample freight payer:
BuyerTerm of payment:
T/T, L/C, D/PCustomized:
YESWarranty:
18 MonthsDelivery Time:
5-7 Working Days For Standard Series; 7-14 Working Days For Customized AC DrivesTransportation:
Express · Sea Freight · Land Freight · Air FreightPackage:
Standard Export Package Carton/WoodAvailability:
OEM/ODM, Minmum Order RequestPlace of Origin:
ChinaShipping Port:
ShenzhenCertification:
CE, EAC, ISO9001, OHSAS18001, TS16949, SGProduct Overview
Item | Description |
Product Name | Heat Pump Drive |
Model Number | V9-R-4TxxNA-64/94 |
Power Range | 7.5kW-30kW |
Rated Input Voltage | 3 phase 380V/480V |
Rated Output Voltage | 3 phase 0 to rated input voltage |
Input Frequency | 50Hz/60Hz |
Applicable Motor | Asynchronous Motor, Synchronous Motor |
Control Mode | V/F Control, Vector Control |
Communication | Dual Modbus Communication (one is a keyboard port) |
IP Code | IP00 |
Overload Capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Technical Features
1. Special-purposed Single PCBA Board Inverter drives for refrigerating compressors
2. Single board structure, all components are integrated, small size, simple convenient installation
3. Optional input filter to improve anti-interference capability
4. It can be connected to external DC reactor to improve power factor, suppress higher harmonic and reduce external conduction and radiation interference
5. Thin film capacitor and electrolytic capacitor are optional, long life of thin film capacitor and high capacitance of electrolytic capacitor. They can be selected according to demand
6. Dual Modbus Communication (one is a keyboard port)
7. Expansion port function is reserved to realize rich expansion functions
Model Explanation
Product Catalogue
V9-R-4T**NA – 64/94 Single Board Drive (Heat Pump Water Heater Drive)
Applicable Motor Power(kW) | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |
Output | Voltage(V) | 3-phase 0 ~ rated input voltage | |||||
Rated Current(A) | 17 | 24 | 30 | 39 | 45 | 60 | |
Max Current(A) | 31 | 43 | 54 | 70 | 81 | 108 | |
Input | Rated voltage/frequency | 3-phase 380V ~ 480v; 50Hz/60Hz | |||||
Allowable Voltage | 323V~528V; Voltage unbalance: 3%; Allowable frequency fluctuation: ± 5% | ||||||
Rated Current(A) | 19 | 26 | 33 | 37 | 42 | 57 | |
Brake unit | Build-in as standard | ||||||
Cooling mode | Natural air cooling |
Technical Specifications
Control characteristics |
Control mode |
Asynchronous motor Sensor-less control/Synchronous motor Sensor-less control |
Starting torque |
Asynchronous motor: |
|
Speed regulation range |
1:200 |
|
Steady speed precision |
± 0.5% |
|
Maximum Frequency |
2000Hz |
|
Torque control |
Yes |
|
Torque control precision |
±5% |
|
Torque response time |
<20ms |
|
Product function |
Key function |
Torque limit, speed control, positioning control, motor auto tune, deep flux-weakening control, current limit control, over-voltage control, under-voltage control, motor speed tracing function, droop control, oscillation suppression, random carrier frequency, inertia auto-tune, etc. |
Speed reference source |
Modbus communication, Keypad, |
|
Modbus communication |
Built in Modbus RTU communication (RS − 485), the standard operation panel can realize the function of remote control box |
|
Protection function |
Power supply under-voltage, over-current protection, over-voltage protection,abnormal baseline,auto-tune fault, module protection, heat-sink overtemperature protection, drive overload protection, motor overload protection, peripheral protection, current abnormal detection, output short-circuit to ground protection,abnormal power loss, abnormal input power supply, EEPROM abnormal detection, abnormal closing of buffer relay,temperature sampling disconnection, encoder disconnection, analog input abnormal detection, motor overtemperature,communication fault, hardware overload protection, etc. |
|
Efficiency |
≥93% |
|
Environment |
Operating site |
● Install vertically in a well-ventilated electrical cabinet. Horizontal or other installation methods are not allowed. |
Ambient temperature |
● −10~+40℃ |
|
Humidity |
5~95%, no condensation is allowed. |
|
Altitude |
● 0~2000 meters |
|
Vibration |
3.5 m/s2 ,2~9Hz;10 m/s2 ,9~200Hz;15 m/s2 ,200~500Hz |
|
Storage temperature |
−40~+70C |
Control Circuit Description
Terminal Type |
Symbol |
Function description |
Technical specifications |
24V |
+24V |
+24V |
24V±10%, internal isolated with GND;Maximum load 200mA, overload and short circuit protection |
PLC |
X terminal power common terminal |
Short to +24V by default |
|
Digital inputs |
X1 |
Multi function input terminal 1 |
Input: 24VDC , 5mA |
Frequency: 0~1KHz Voltage: 24V±20% |
|||
COM |
X terminal power common terminal |
Internal isolation from GND |
|
GND |
GND |
Analog GND |
10V power supply grounding or shielding grounding of 485 communication |
10V power supply |
10V |
10V power supply |
|
Analog inputs |
AI1 |
Analog input 1 |
Select 0 / 4mA ~ 20mA or 0 ~ 10V through jumper |
RS485 |
485− |
RS485 negative end |
|
485+ |
RS485 positive end |
|
|
Relay outputs |
RA |
Relay outputs |
RA-RB:Normally closed |
RB |
RA-RC: Normally open |
||
RC |
Contact capacity: 250VAC/1A |
Terminal Wiring
V9-R Multi-function operation keyboard
1. Chinese / English LCD keyboard, 5-digit LED digital tube keyboard (optional)
2. Key design in accordance with physical engineering
3. It can be extended by direct standard network cable, which is very suitable for installation in the control cabinet
4. Parameters can be backed up and downloaded through the keyboard
5. Contents displayed on the keyboard are very rich and clear
6. Optional 5-digit digital tube operation keyboard
Drive Installation Dimension
Installation dimension of input filter
Applications
|
|
|
|
|
|
|
|
Heat Pump Controller Representative Industry
Central Air Conditioner, HP Water Heater Controller, Refrigerating Compressor, Water-source Heat Pump and Air-source Heat Pump Systems and other fields.
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Categories
Copyright © 2024 Shenzhen V&T Technologies Co.,Ltd.. All Rights Reserved. Power by