AIEC3300 series elevator controller support multiple motor control modes and encoder types, integrate advanced communication protocol, greatly improve the efficiency of elevator operation. support parallel/group control and provides multiple scheduling algorithms to meet the different requirements for customers.
Sample provide:
YESSample freight payer:
BuyerTerm of payment:
T/T, L/C, D/PCustomized:
YESWarranty:
18 MonthsDelivery Time:
5-7 working days for standard series; 7-14 working days for customized AC drivesTransportation:
Express · Sea freight · Land freight · Air freightPackage:
Standard Export Package Carton/WoodAvailability:
OEM/ODM, Minmum Order RequestPlace of Origin:
ChinaShipping Port:
ShenzhenCertification:
CE, EAC, ISO9001, OHSAS18001, TS16949, SGSProduct Overview
Item
Description
Product Name
Integrated Elevator Inverter / Elevator AC Drive
Model Number
AIEC3300−C−40xxx
Power Range
2.2kW-75kW
Rated Input Voltage
3 phase 380V/480V
Rated Output Voltage
3 phase 0 to rated input voltage
Input Frequency
50Hz/60Hz
Applicable Motor
Asynchronous Motor, Synchronous Motor
Control Mode
Closed loop vector control with PG card
Communication
Modbus 485 RTU, CAN
IP Class
Standard IP20
Overload Capacity
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
Feature
■ V&T Elevator Inverter adopts advanced vector control technology to realize precise decoupling of the motor and exploit fully motor performance;
■ Direct stopping technology based on the principle of distance control to improve elevator operation efficiency;
■ Double safety design, intelligent fault handling, more protection, worry-free use;
■ Enhanced CAN, RS485 communication technology, strong communication anti-interference ability, high efficiency;
■ Apply Internet of Things technology to realize remote upgrade and debugging functions;
Model Explanation
Product Catalogue
AIEC3300−C−40□□□ ; Three−phase 380V application
Power (kW) | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Motor power (kW) | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage | ||||||||||||
Rated current (A) | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||
Input | Rated voltage/frequency | Three−phase 380V/480V; 50Hz/60Hz | ||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||
Rated current (A) | 6.1 | 10 | 15 | 19 | 26 | 33 | 43 | 50 | 66 | 83 | 100 | 123 | 165 | |
Braking unit | Built−in as standard | Built−in is optional | ||||||||||||
Protection class | IP 20 | |||||||||||||
Cooling mode | Natural cooling | Forced air convection cooling |
AIEC3300−C−20□□□ ; Single−phase / Three−phase 220V application
Power (kW) |
2.2 |
3.7 |
5.5 |
|
Motor power (kW) |
2.2 |
3.7 |
5.5 |
|
Output |
Voltage (V) |
Three−phase 0 to rated input voltage |
||
Rated current (A) |
10.0 |
14.0 |
27.0 |
|
Overload capacity |
150% rated current for 60 seconds; 200% rated current for 10 seconds |
|||
Input |
Rated voltage/ frequency |
Three−phase or single−phase 200V~240V; 50Hz/60Hz |
||
Allowable voltage range |
180V ~ 260V; Voltage unbalancedness ≤3%; allowable frequency fluctuation: ±5% |
|||
Rated current (A) |
12.0 |
17.0 |
29.0 |
Technical Specifications
Basic features |
Standard floor |
40 floors |
Elevator running speed |
≤ 4.00m/s |
|
Number of elevators in parallel/group mode |
≤ 4 sets |
|
Communication mode |
CAN /RS485/RS232 |
|
Control features |
Motor control mode |
Closed loop vector control with PG card |
Startup torque |
Up to 200% (depending on load) |
|
Speed range |
1:1000(Closed loop vector control with PG card) |
|
Speed control precision |
±0.05% (Closed loop vector control with PG card, 25±10℃) |
|
Torque limit |
200% of the rated torque |
|
Torque precision |
±5% |
|
No−load startup compensation |
When the elevator load is unknown, the system compensates the appropriate torque for the motor according to the running direction of the elevator, so as to make it start smoothly, minimize the car sliding at the moment of starting, and increase the comfort of elevator starting. |
|
Carrier frequency |
2~16kHz |
|
Product functions |
Key functions |
See product introduction for details |
Frequency range |
0~99Hz |
|
Acceleration/ deceleration time |
0.1~8s |
|
150% |
||
Special functions |
Protecting anti−plug |
Perfect protection circuit design, any wrong insertion will not damage, and will not affect other controller. |
Unique communication anti−interference |
In order to improve the anti−interference performance, the car top board and the main control board use the enhanced CAN communication technology, without shielding wire. |
|
Energy saving operation of standby power supply |
When the normal power supply is interrupted and the emergency power supply is used, the system reduces the running speed of the elevator in the prerequisite of guaranteeing the smooth running curve and stop at the nearest floor.Open the door first, close door after delay for a period of time, press any key in the car to open the door. |
|
Troubleshooting based on fault level |
Faults are classified into different levels based on the severity. Different levels of faults are rectified using different methods, improving the system operation efficiency. |
|
Auto−leveling |
The system implements automatic accurate leveling based on the floor pulse counting and up/down leveling feedback signals. |
|
Door pre−open function |
In automatic running state, when the elevator speed is smaller than 0.25 m/s and the door zone signal is active, the system shorts the door lock by means of the shorting door lock circuit relay and outputs the door open signal, implementing door pre−open. This improves the elevator use efficiency. |
|
Micro−leveling |
After landing at a floor, the elevator may move upward or downward due to the load change and the car door is not aligned with the ground, which is inconvenient for passengers and goods in and out. In this case, the system allows the elevator to run to the leveling position in the door open state at the re−leveling speed. |
|
Protection function |
Motor over−load protection, controller over−load protection, short circuit protection, input lost ;phase protection, output lost phase protection, over−voltage protection, under voltage protection, instantaneous power failure compensation, heatsink overheating, stall prevention, pulse encoder failure, brake unit protection, module protection, current sensor protection, speed abnormality protection, output short to ground protection, output imbalance protection, braking ;resistor short circuit protection, speed abnormality protection, running time limiter protection, level switch fault protection, EEPROM abnormal. |
|
PG card |
PG card type |
Support push−pull, open collector and SIN/COS encoder. |
I/O signal |
Optocoupler input control power supply |
Isolation 24 VDC |
Low voltage optocoupler isolation input |
24 x digital inputs. Optocoupler control signals are isolation 24 VDC power input signals. |
|
Low voltage optocoupler isolation input |
4 x digital outputs |
|
Relay output |
6 normally open contacts, single−pole single−throw, 5 A contact switchover capability. Contact load (Resistive): 5A250VAC or 5A28VDC |
|
USB interface |
Commissioning by cell phone, IoT monitoring |
|
CAN communication interface |
2 communication ports (Car top communication, parallel or group control) |
|
MODBUS communication |
2 communication ports (Outbound communication, Internet of Things) |
|
Analog input port |
1 single−ended or differential input, input voltage range −10 V to +10 V, precision 0.1% |
|
Operation and display |
Operation panel、Keypad、Mobile phone commissioning |
|
Environment |
Operating site |
The product shall be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling media is the air. The product shall be installed in the environment free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam and drip. |
Ambient temperature |
−10 ~ +40ºC, derated at 40 ~ 50ºC, the rated output current shall be decreased by 1% for every temperature rise of 1ºC |
|
Humidity |
5 ~ 95%, no condensing |
|
Altitude |
0 ~ 2000m, derated above 1000m, the rated output current shall be decreased by 1% for every rise of 100m |
|
Vibration |
Less than 5.9 m/s 2 (0.6 g) |
|
IP level |
IP20 |
|
Power distribution system |
TN/TT |
|
Pollution degree |
PD2 |
|
Storage temperature |
−20~+60℃ |
Control Circuit Terminals
Type |
Terminal |
Description |
Keypad 485 |
CN12 |
RS485 port of keypad |
Terminal communication |
24V |
24V power supply for the board |
COM |
||
MOD+ |
Standard isolation RS−485,modbus communication for hall call and display |
|
MOD− |
||
CAN+ |
CAN communication, connect with car top board, machine−room−less monitoring board and DI/DO expansion board |
|
CAN− |
||
Digital input |
X1~X24 |
Input voltage range ;10Vdc~30Vdc Input resistance:4.7kΩ, current limit 5mA The function of digital input is setting by parameters of F5−01 to F5−24 |
COM |
Digital input common end |
|
X25~X28 |
High voltage input, input voltage: 110VAC ±15%,110VDC ±20% Safety circuit feedback and door lock feedback. |
|
Analog input |
AI |
Differential input, input voltage range −10 V to +10 V, it is used for load−cell |
Relay output |
Y1/M1~ ;Y6/M6 |
Relay output terminal NO: 5A/250Vac The relay output function is setting by parameters of F5−26 to F5−31 |
Group control |
CAN2+ |
CAN2 communication interface, for group or parallel/group control |
CAN2− |
||
COM |
||
IoT communication |
CN8 |
IoT communication interface |
Installation dimension
|
|
AIEC3300−C−4007 and above power class
Product appearance, installation dimensions, approximate weight
Voltage( V) |
Elevator integrated controller model |
Dimension (mm) |
Gross weight (kg) |
||||||
W |
H |
D |
W1 |
H1 |
T1 |
Mounting hole diameter |
|||
Single−phase /Three−phase 220 |
AIEC3300−C−2002 |
198 |
302 |
143 |
160 |
289 |
1.5 |
8 |
6 |
AIEC3300−C−2003 |
|||||||||
Three−phase 380 |
AIEC3300−C−4007 |
198 |
302 |
164 |
160 |
289 |
1.5 |
8 |
8 |
AIEC3300−C−4011 |
|||||||||
AIEC3300−C−4015 |
|||||||||
AIEC3300−C−4018 |
223 |
351 |
195 |
195 |
335 |
1.5 |
8 |
10 |
|
AIEC3300−C−4022 |
|||||||||
AIEC3300−C−4030 |
264 |
430 |
217 |
230 |
418 |
1.5 |
8 |
18 |
|
AIEC3300−C−4037 |
|||||||||
AIEC3300−C−4045 |
305 |
548 |
255 |
245 |
523 |
1.5 |
10 |
35 |
|
AIEC3300−C−4055 |
|||||||||
AIEC3300−C−4075 |
338 |
580 |
310 |
270 |
560 |
1.5 |
10 |
52 |
Applications
Representative Industry
As the China Elevator Drive Manufacturer, The integrated elevator drive of Shenzhen V&T Technologies Co.,Ltd. is suitable for passenger elevator industry, Inverter for cargo Lifting, Inverter for escalator, Inverter for freight elevator etc.
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Categories
Copyright © 2024 Shenzhen V&T Technologies Co.,Ltd.. All Rights Reserved. Power by
IPv6 network supported