As the VFD manufacturer in china, V&T has rich experience in electric drive fields. V&T V9−H Series General Purpose Inverter is a high-performance vector control and torque controlled frequency drive. Vector control technology and torque control technology are employed. It can better meet the needs of various transmission applications.Voltage range covers 200V, 400V, 690V, and 1140V. The product power range covers 0.4kW to 3MW.
Sample provide:
YESSample freight payer:
BuyerTerm of payment:
T/T, L/C, D/PCustomized:
YESWarranty:
18 MonthsDelivery Time:
5-7 working days for standard series; 7-14 working days for customized AC drivesTransportation:
Express · Sea freight · Land freight · Air freightPackage:
Standard Export Package Carton/WoodAvailability:
OEM/ODM, Minmum Order RequestPlace of Origin:
ChinaShipping Port:
ShenzhenCertification:
CE, EAC, ISO9001, OHSAS18001, TS16949, SGS
Product Overview
Item
Description
Product Name
Frequency Inverter/ AC Drive
Model Number
V9-H-4TxxG/xxL
Power Range
0.75kW-630kW
Rated Input Voltage
3 phase 380V/480V
Rated Output Voltage
3 phase 0 to rated input voltage
Input Frequency
50Hz/60Hz
Applicable Motor
Asynchronous Motor, Synchronous Motor
Control Mode
V/F Control, Vector Control, Sensorless Vector Control, Sensor Vector Control, Vector Torque Control
Communication
Modbus 485 RTU, CANOpen, Profibus-DP, Profinet
IP Class
Standard IP20
Overload Capacity
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
Feature
■ Fast and accurate motor parameter self-learning, suitable for a variety of motors: synchronous/asynchronous/reluctance/high-speed/torque motor, VF vector encoder closed loop integrated
■ Automation Drives Asynchronous and non-inductive VF control, 200% torque output at 0.25Hz in electric state, 200% torque output at 1Hz in power generation state
■ Good voltage and current control, high speed, high frequency, deep field weakening, wave-by-wave current limiting, multiple protections
■ Modular compact structure design, high power density
■ Support multiple encoders and multiple high-speed communication protocols
■ Integrated drive and control, expandable PLC and motion control card
■ Multiple language keyboard, friendly interface, reliable and easy to use
Model Explanation
Product Catalogue
V9−H−4T□□□G Three-phase 400V constant torque / heavy duty application
Power(kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
Motor power (kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
Output
Voltage (V)
3-phase 0 -rated input voltage
Rated current (A)
2.5
3.8
5.5
9
13
17
24
30
39
45
60
75
91
112
150
176
210
Overload capability
150% 1min,180% 10s, 200% 0.5s,10min interval (Inverse-time characteristic)
Input
Rated voltage / frequency
3-phase 380V-480V;50Hz/60Hz
Allowable voltage
323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Rated current (A)
2.8
4.2
6.1
10
15
19
26
33
43
50
66
83
100
123
165
194
231
Brake unit
Standard built-in
Built-in brake unit is optional
Protection level
IP20
Cooling method
Self−cooling
Forced cooling
Power(kW)
132
160
185
200
220
250
280
315
355
400
450
500
560
630
Motor power (kW)
132
160
185
200
220
250
280
315
355
400
450
500
560
630
Output
Voltage (V)
3-phase 0 -rated input voltage
Rated current (A)
253
304
350
380
426
470
520
600
650
690
775
860
950
1100
150% 1min,180% 10s, 200% 0.5s,10min interval (Inverse-time characteristic)
Input
Rated voltage / frequency
3-phase 380V-480V; 50Hz/60Hz
Allowable voltage
323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Rated current (A)
232
282
326
352
385
437
491
580
624
670
755
840
920
1050
Brake unit
External braking unit needed
Protection level
IP20
Cooling method
Forced cooling
Note:
0.75kW~15kW:No built-in DC reactor ;
18.5kW~110kW:Optional DC reactor ;
132kW~160kW:Standard built-in DC reactor ;
185kW~500kW:Standard external DC reactor;
560kW~630kW:Standard built-in AC input reactor;
Higher power level product can be customized
220V, 690V, 1140V and other voltage level inverters can be customized.
V9−H−4T□□□L Three−phase 400V Variable torque/light−duty application
Power(kW)
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
Motor power (kW)
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
Output
Voltage(V)
3-phase 0 -rated input voltage
Rated current (A)
3.3
5
7.5
11
17
22
29
35
45
57
70
91
110
144
180
216
242
Overload capability
120% 1min,160% 0.5s,10min interval (Inverse-time characteristic)
Input
Rated voltage /frequency
3-phase 380V-480V;50Hz/60Hz
323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Rated current (A)
3.6
5.5
8.3
12
19
25
32
39
50
61
77
100
121
158
198
238
266
Brake unit
Standard built-in
Built-in brake unit is optional
Protection level
IP20
Cooling method
Self−cooling
Forced cooling
Power(kW)
160
185
200
220
250
280
315
355
400
450
500
560
630
710
Motor power (kW)
160
185
200
220
250
280
315
355
400
450
500
560
630
710
Output
Voltage (V)
3-phase 0 -rated input voltage
325
365
405
440
495
547
610
695
770
866
950
1100
1200
1300
Overload capability
120% 1min,160% 0.5s,10min interval (Inverse-time characteristic)
Input
Rated voltage /frequency
3-phase 380V-480V; 50Hz/60Hz
323V-528V; degree of voltage unbalance:≤3%; allowable frequency fluctuations:±5%
Rated current (A)
282
326
352
385
437
491
580
670
755
840
920
1050
1150
1250
Brake unit
External braking unit needed
Protection level
IP20
Cooling method
Forced cooling
Note:
1.5kW - 18.5kW: No built-in DC reactor ;
22kW~132kW: Optional DC reactor ;
160kW~185kW: Standard built-in DC reactor ;
200kW~560kW: Standard external DC reactor ;
630kW~710kW: Standard built-in AC input reactor;
Higher power level product can be customized ;
220V, 690V, 1140V and other voltage level inverters can be customized.
Technical Specification
Control characteristics |
Control ;mode |
Sensor-less control |
Sensor control |
Applicable motor type |
Synchronous motor Asynchronous motor |
Synchronous motor Asynchronous motor |
|
Starting torque |
● Asynchronous motor: 200% of rated torque at 0.25Hz ● Synchronous motor: 150% of rated torque at 1.5% of rated speed
|
200% of rated torque at 0 speed |
|
Speed regulation range |
1:200 |
1:5000 |
|
Steady speed precision |
± 0.5% |
± 0.02% |
|
Maximum speed |
VF control: 600Hz Vector control: 600 Hz ;
Note: Higher frequency products can be customized |
600Hz Note: Higher frequency products can be customized |
|
Torque control |
Y |
Y |
|
Torque control precision |
±5% |
±3% |
|
Torque response time |
<20ms |
<10ms |
|
Positioning control |
N |
Y |
|
Positioning precision |
N |
±1 ;pulse |
|
Product function |
Key function |
Torque limit, speed control, positioning control, motor auto tune, deep flux-weakening control, current limit control, over-voltage control, under-voltage control, motor speed tracing function, droop control, oscillation suppression, random carrier frequency, inertia auto-tune, etc. |
|
Speed reference source |
Modbus communication, Keypad, external digital input, analog ;AI1/AI2/AI3, high speed pulse input, simple PLC, PID, CAN, PROFIBUS DP, PROFINET, etc. |
||
Dynamic brake |
Brake unit action voltage: 650 ~ 750V. The brake unit can be built-in for 110kW and below equipment ● 0.75~15kW: brake unit is built- in as standard. ● 18.5~110kW: brake unit is built- in as optional. |
||
Communication |
Built-in Modbus-RTU communication, the maximum distance up to 500 meters. |
||
Keypad |
LED Keypad and LCD Keypad are optional the Keypad can be used as remote-control box via straight-through wired cable. |
||
Common DC bus |
Support common DC bus ;directly |
||
Independent air duct |
All series product adopts independent duct design |
||
Protection function |
Power supply under-voltage, over-current protection, over-voltage protection, auto-tune fault, module protection, heat-sink over-temperature protection, drive overload protection, motor overload protection, peripheral protection, current abnormal detection, output short-circuit to ground protection, EEPROM abnormal detection, temperature sampling disconnection, encoder disconnection, analog input abnormal detection, motor over-temperature, communication fault, hardware overload protection, etc. |
||
Efficiency |
At rating condition: ● 0.75kW to 7.5kW: ≥ 93% ● 11kW to 45kW: ≥ 95% ● 55kW and higher power class: ≥ 98% |
||
Environment |
Operating site |
● Install vertically in a well-ventilated electrical cabinet. Horizontal or other installation methods are not allowed. ● The cooling medium is air. ● Installed in an environment free from direct sunlight, dust, corrosive gases, flammable gases, no oil mist, no steam, no dripping. |
|
Ambient temperature |
● −10~+40℃ ● Derating use when the temperature between 40 to 50℃, the rated output current is reduced by 1% for every 1 °C increasing. |
||
Humidity |
5~95%, ;no condensation is allowed. |
||
Altitude |
● 0~2000 meters ● Derating use when the altitude over 1000 meters, the rated output current is reduced by 1% for every 100-meter rising. |
||
Vibration |
● 3.5 m/s2, 2~9Hz ● 10 m/s2, 9~200Hz ● 15 m/s2, 200~500Hz |
||
Storage temperature |
−40~+70℃. |
Motor Wiring
Short circuit or grounding of the AC Motor Drives output terminals is prohibited. Otherwise, it will cause damage to the internal components of the drive.
Avoid output cables (U/V/W) short circuit or short circuit to enclosure, otherwise there is a risk of electric shock.
It is strictly forbidden to connect a capacitor or phase lead LC/RC noise filter to the output of the 3 phase 380V AC Drive, otherwise the drive will be damaged.
When a contactor is installed between the drive and the motor, the switching action of the output contactor cannot be performed during the operation of the drive, otherwise a large current will flow into the drive to and the drive will report fault information.
Cable length between drive and motor: When the cable between the RS485 Modbus Frequency Drive and the motor is too long, the high-order harmonic leakage current at the output will adversely affect the drive and peripheral devices. It is recommended to install a output AC reactor when the motor cable exceeds 100 meters, and contact the manufacturer to inquire whether the carrier frequency needs to be modified.
Installation dimension
|
|
V9−H−4T7.5G/11L and below power class
|
|
V9−H−4T11G/15L and above power class
Voltage |
Model |
Outline and mounting dimension (mm) |
Weight (kg) |
||||||
W |
H |
D |
W1 |
H1 |
T1 |
Mounting hole diameter d |
|||
400V |
V9−H−4T0.75G/1.5L |
118 |
190 |
155 |
105 |
173 |
3 |
5.5 |
1.5 |
V9−H−4T1.5G/2.2L |
118 |
190 |
175 |
105 |
173 |
4 |
5.5 |
2.6 |
|
V9−H−4T2.2G/3.7L |
|||||||||
V9−H−4T3.7G/5.5L |
|||||||||
V9−H−4T5.5G/7.5L |
155 |
249 |
185 |
136 |
232 |
8 |
5.5 |
3 |
|
V9−H−4T7.5G/11L |
|||||||||
V9−H−4T11G/15L |
198 |
299 |
190 |
160 |
283 |
1.2 |
6 |
8 |
|
V9−H−4T15G/18.5L |
|||||||||
V9−H−4T18.5G/22L |
223 |
348 |
208 |
195 |
335 |
1.5 |
6 |
10 |
|
V9−H−4T22G/30L |
|||||||||
V9−H−4T30G/37L |
264 |
430 |
235 |
230 |
418 |
1.5 |
7 |
18 |
|
V9−H−4T37G/45L |
|||||||||
V9−H−4T45G/55L |
305 |
545 |
270 |
245 |
523 |
1.5 |
10 |
35 |
|
V9−H−4T55G/75L |
|||||||||
V9−H−4T75G/90L |
338 |
580 |
310 |
270 |
560 |
1.5 |
10 |
52 |
|
V9−H−4T90G/110L |
|||||||||
V9−H−4T110G/132L |
|||||||||
V9−H−4T132G/160L |
400 |
917 |
323 |
320 |
890 |
3.0 |
12 |
75 |
|
V9−H−4T160G/185L |
|||||||||
V9−H−4T185G/200L |
540 |
890 |
385 |
370 |
855 |
4.0 |
14 |
85 |
|
V9−H−4T200G/220L |
|||||||||
V9−H−4T220G/250L |
540 |
890 |
416 |
370 |
855 |
4.0 |
14 |
85 |
|
V9−H−4T250G/280L |
700 |
1010 |
385 |
520 |
977 |
4.0 |
14 |
125 |
|
V9−H−4T280G/315L |
|||||||||
V9−H−4T315G/355L |
700 |
1010 |
418.5 |
520 |
977 |
4.0 |
14 |
125 |
|
V9−H−4T355G/400L |
810 |
1358 |
425 |
520 |
1300 |
4.0 |
14 |
215 |
|
V9−H−4T400G/450L |
810 |
1358 |
425 |
520 |
1300 |
4.0 |
14 |
215 |
|
V9−H−4T450G/500L |
|||||||||
V9−H−4T500G/560L |
Applications
|
|
|
|
|
|
|
|
|
Representative Industry
AC drives are used to bring about process and quality improvements in industrial and commercial applications' acceleration, flow, monitoring, pressure, speed, temperature, tension, and torque. Whenever a load has either a variable torque or a variable speed, a VFD should be considered to control torque and speed. V9 series universal speed AC drive of Shenzhen V&T Technologies Co.,Ltd. is suitable for Compressor Drives, Pump Drives, Printing Packaging, Petrochemical, Textile, Cable Machinery, Food Packaging, Electric Vehicles, Plastic Machinery, Metal Products Equipment, Centrifuges and High-end applications requiring closed-loop vector or torque control.
Previous:
3.7kW-15kW V9 Series High Performance Universal Speed AC DriveNext:
75kW-220kW V9 Series High Performance Universal Speed AC DriveIf you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Categories
Copyright © 2024 Shenzhen V&T Technologies Co.,Ltd.. All Rights Reserved. Power by
IPv6 network supported