V5-H-6T and V5-H-BT medium voltage series are high-performance vector control inverter. The product adopts the open-loop vector control technology with the current international advanced technology, which has the same excellent control performance with the international high-end drive. It further strengthened the reliability and environmental adaptability of the product, as well as the customized and professional design. This greatly meet the needs of various transmission applications.
Sample provide:
YESSample freight payer:
BuyerTerm of payment:
T/T, L/C, D/PCustomized:
YESWarranty:
18 MonthsDelivery Time:
5-7 working days for standard series; 7-14 working days for customized AC drivesTransportation:
Express · Sea freight · Land freight · Air freighPackage:
Standard Export Package Carton/WoodAvailability:
OEM/ODM, Minmum Order RequestPlace of Origin:
ChinaShipping Port:
ShenzhenCertification:
CE, EAC, ISO9001, OHSAS18001, TS16949, SGSProduct Overview
Item | Description |
Product Name | Frequency Inverter/ AC Drive |
Model Number | V5-H-6TxxxG, V5−H−BTxxxG |
Power Range | 15kW-710kW |
Rated Input Voltage | 3 phase 380V/480V |
Rated Output Voltage | 3 phase 0 to rated input voltage |
Input Frequency | 50Hz/60Hz |
Applicable Motor | Asynchronous Motor |
Control Mode | V/F Control, Vector Control, Sensor-less Vector Control, Vector Torque Control |
Communication | Modbus 485 RTU |
IP Class | Standard IP20 |
Overload Capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Medium Voltage Drives Feature
■ V&T Vector Torque Drive Higher saving-energy effect and Less reactive current
■ Outdoor digital control cabinet, thermostatic control cabinet suit ,high and low temperature ambient for long-term reliable work
■ Excellent control performance for open-loop vector control, accurate speed identification and rotor flux orientation, and torque can respond quickly and operate stably at 0.25hz load change
■ Excellent current and voltage control technology, repeatedly and alternately accelerated and decelerated with 0.1s instruction, and inverter operates stably ;
■ Wide voltage ;range, low voltage ;under fluctuated power, continuous working, strong adaptability
■ Convenient and continuous to adjust speed, perfect torque compensation function, normal to start motor with powerful power.
■ Mature power balance scheme can effectively solve power distribution in multi-point transmission.
■ The overload capacity can be optimized under low frequency.
■ Rich monitoring function, operation data can be recorded and saved by storage medium or wireless transmission.
Model Explanation
Product Catalogue
V5−H−6T□□□G ; 3 Phase 690V Constant Torque/Heavy-duty Applications
Power(kW) | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 | 220 | |
Motor(kW) | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 | 220 | |
Output | Voltage(V) | 3 phase 0~Rated Voltage | ||||||||||||||
Rated Current(A) | 20 | 25 | 28 | 35 | 45 | 52 | 65 | 86 | 98 | 120 | 150 | 176 | 204 | 220 | 245 | |
Overload capacity | 150% 1min,180% 10 second, 200% 0.5 second,interval: 10 minutes (inverse time lag ;feature) | |||||||||||||||
Input | Voltage/ frequency | 3 phase 690V~790V;50Hz/60Hz | ||||||||||||||
Allowable voltage range | 587V~793V;Voltage imbalance:≤3% ;allowable frequency fluctuation:±5% | |||||||||||||||
Rated Current(A) | 25 | 30 | 35 | 40 | 47 | 52 | 65 | 85 | 96 | 116 | 145 | 168 | 196 | 210 | 230 | |
*Braking unit | Built-in as standard | External braking unit needed | ||||||||||||||
IP | IP20 | |||||||||||||||
Cooling mode | Forced air cooling | |||||||||||||||
Power(kW) | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 |
|
|
|
|
|
|
|
Motor(kW) | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 |
|
|
|
|
|
|
|
Output | Voltage(V) | 3 phase 0~Rated Voltage | ||||||||||||||
Rated Current(A) | 275 | 325 | 350 | 395 | 435 | 490 | 545 | 600 | 680 |
|
|
|
|
|
|
|
Overload capacity | 150% 1min,180% 10 second, 200% ;0.5 second,interval: 10 minutes (inverse time lag ;feature) | |||||||||||||||
Input | Voltage/ frequency | 3 phase 690V~790V;50Hz/60Hz | ||||||||||||||
Allowable voltage range | 587V~793V;Voltage imbalance:≤3% ;allowable frequency fluctuation:±5% | |||||||||||||||
Rated Current(A) | 255 | 290 | 335 | 378 | 415 | 466 | 520 | 580 | 655 |
|
|
|
|
|
|
|
*Braking unit | External braking unit needed | |||||||||||||||
IP | IP20 | |||||||||||||||
Cooling mode | Forced air cooling |
V5−H−BT□□□G ; 3 Phase 1140V Constant Torque/Heavy-duty Applications
Power(kW) |
37 |
45 |
55 |
75 |
90 |
110 |
132 |
160 |
185 |
200 |
220 |
250 |
280 |
315 |
355 |
|
Motor(kW) |
37 |
45 |
55 |
75 |
90 |
110 |
132 |
160 |
185 |
200 |
220 |
250 |
280 |
315 |
355 |
|
Output |
Voltage(V) |
3 phase 0~Rated Voltage |
||||||||||||||
Rated Current(A) |
25 |
31 |
38 |
52 |
58 |
73 |
86 |
104 |
115 |
132 |
144 |
162 |
180 |
208 |
225 |
|
Overload capacity |
150% 1 min,180% 10 second, 200% 0.5 second,interval: 10 minutes (inverse time lag ;feature) |
|||||||||||||||
Input |
Voltage/ frequency |
3 phase 1140V;50Hz/60Hz |
||||||||||||||
Allowable voltage range |
960V~1300V;Voltage imbalance:≤3% ;allowable frequency fluctuation:±5% |
|||||||||||||||
Rated Current(A) |
27 |
32 |
38 |
51 |
57 |
72 |
85 |
102 |
113 |
126 |
141 |
158 |
180 |
200 |
215 |
|
IP |
IP20 |
|||||||||||||||
Cooling mode |
Forced air cooling |
|||||||||||||||
Power(kW) |
400 |
450 |
500 |
560 |
630 |
710 |
|
|
|
|
|
|
|
|
|
|
Motor(kW) |
400 |
450 |
500 |
560 |
630 |
710 |
|
|
|
|
|
|
|
|
|
|
Output |
Voltage(V) |
3 phase 0~Rated Voltage |
||||||||||||||
Rated Current(A) |
260 |
300 |
325 |
365 |
400 |
450 |
|
|
|
|
|
|
|
|
|
|
Overload capacity |
150% 1 min,180% 10 second, 200% 0.5 second,interval: 10 minutes (inverse time lag ;feature) |
|||||||||||||||
Input |
Voltage/ frequency |
3 phase 1140V;50Hz/60Hz |
||||||||||||||
Allowable voltage range |
970V~1300V;Voltage imbalance:≤3% ;allowable frequency fluctuation:±5% |
|||||||||||||||
Rated Current(A) |
260 |
300 |
325 |
365 |
400 |
450 |
|
|
|
|
|
|
|
|
|
|
IP |
IP20 |
|||||||||||||||
Cooling mode |
Forced air cooling |
Technical Specification
Control characteristics |
Control mode |
Vector Control |
Starting torque |
0.50Hz ;180% |
|
Speed regulation range |
1:100 |
|
Steady speed precision |
± ;0.5% |
|
Product functions |
Key function |
Under-voltage regulation, switchover of run command source(operation panel, terminal and communication), speed tracing function, multi− step frequency reference(up to 23 step frequency),S curve acceleration and deceleration, slip compensation, PID regulation, droop control, current limit, manual torque boost and auto torque boost,Multiple function input/output terminal. |
Frequency setting method |
operation panel setting、terminal UP/DN、upper computer communication、analog AI1, analog AI2,analog AI3、pulse DI, etc. |
|
Frequency range |
0.00~300.00Hz |
|
Starting frequency |
0.00~60.00Hz |
|
Acceleration time and deceleration time |
0.1~36000s |
|
Dynamic braking |
Braking unit action voltage: AC690V: 800~1200V AC1140V:1700~2200V |
|
DC braking |
DC braking start frequency:0.00~300.00Hz; DC braking current:0.0~120.0%; DC braking time:0.0~30.0s;DC braking function does not required waiting time to start ;to realize quick braking |
|
Magnetic flux braking |
Enabled or disabled during deceleration are optional, the default setting is enabled |
|
Unique functions |
Multi-function M key |
The unique multi-function key can be set to frequently used operations: such as JOG, emergency stop, switchover of run command source, switchover of parameters display mode, etc. |
Multiple parameter display modes |
Basic parameters display mode, fast parameters display mode, non−factory setting parameters display mode. |
|
Parameters copy |
The standard operation panel can realize the parameters upload, download and display the copy progress. Users can set to forbid overwriting the uploaded parameters |
|
Function code hiding |
Customers can customize the display and hide of any function code group |
|
Dual 485 communication ports |
Dual 485 communication ports support Modbus protocol (RTU). The maximum distance is 500 meters |
|
Operation panel |
Key type operation panel, Protection level: IP20 as standard, IP54 as option |
|
Common DC bus |
All series product support common DC bus |
|
Independent duct |
All series product adopts independent duct design and supports the installation of heat-sink outside the cabinet |
|
Power-On-Self-Test (POST) |
Realizing the POST of internal and peripheral circuits, including motor grounded, abnormal +10V power supply output, analog input and disconnection, etc. |
|
Protection function |
Power supply under-voltage, over-current protection, over-voltage protection, interference protection, abnormal comparison level, motor data identification ;failure, module(IPM) protection, heat-sink over temperature protection, inverter overload protection, motor overload protection, peripheral protection, abnormal current detection, output short circuit to ground, interruption of power supply when in running status, abnormal input power, output phase loss, abnormal EEPROM protection, abnormal pre-charging contactor detection, temperature sampling disconnection, abnormal +10V power supply, abnormal analog input, motor over temperature protection(PTC), abnormal communication, abnormal software version compatibility, abnormal copying, terminal mutual exclusion detection, hardware overload protection |
|
Environment |
Operating site |
The product should be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling medium is the air. The product should be installed in the environment without dust, corrosive gas, combustible gas, oil mist, steam, drip and free from direct sunlight.Please install it in a place where it cannot be severe vibration and shock, and the maximum amplitude does not exceed 5.8m/S2 (0.6g) |
Ambient temperature |
−10 to +40ºC, the product must be de-rated rated output current for the ambient temperature between 40ºC to 50ºC, the rated output current must be de-rated for 1% per 1ºC temperature rise |
|
Humidity |
5 to 95%, no condensing |
|
Altitude |
0 to 2000m, the product must be de-rated rated output current for the altitude above 1000 meters, the rated output current must be de-rated for 1% per 100 meters rise |
|
Vibration |
3.5mm, 2~9Hz;10 m/s2,9~200Hz;15 m/s2,200~500Hz |
|
Storage temperature |
−40~+70℃ |
Function of Control Circuit Terminal
Installation Dimension
690V Voltage Class
|
|
V5−H−6T90G And below power class
|
|
|
V5−H−6T110G And above power class(accompany with pedestal )
|
|
V5−H−6T110G And above power class(no pedestal)
V5−H−6T Series Product Appearance,Installation Dimensions, Approximate Weight
Voltage |
power(kW) |
pedestal |
Appearance size(mm) |
Installation Dimensions(mm) |
Weight(kg) |
||||||
W |
H |
D |
W1 |
H1 |
D1 |
T1 |
Hole d |
||||
690V |
15~30 |
No |
285 |
440 |
220 |
200 |
425 |
107.5 |
2.5 |
7 |
17 |
37~55 |
No |
315 |
575 |
227 |
220 |
553 |
123.5 |
2.5 |
10 |
25 |
|
75~90 |
No |
400 |
615 |
265 |
270 |
590 |
123.5 |
3.0 |
10 |
35 |
|
110~132 |
yes |
465 |
1042 |
325 |
382 |
339 |
238 |
— |
14 |
— |
|
No |
465 |
745 |
325 |
343 |
715 |
156 |
3.0 |
12 |
55 |
||
160~220 |
yes |
540 |
1206 |
385 |
459 |
365 |
300 |
— |
14 |
— |
|
No |
540 |
890 |
385 |
370 |
855 |
205.5 |
4.0 |
14 |
85 |
||
250~355 |
yes |
700 |
1380 |
385 |
614 |
412 |
294 |
— |
15 |
— |
|
No |
700 |
1010 |
385 |
520 |
977 |
210 |
4.0 |
14 |
125 |
||
400~630 |
yes |
810 |
1698 |
425 |
728 |
418 |
339 |
— |
15 |
— |
|
No |
810 |
1358 |
425 |
520 |
1300 |
210 |
4.0 |
14 |
215 |
Note: For 690V series inverters, air-cooled inverters are standard products, and explosion-proof inverters need to be customized according to customer needs. The installation dimensions of explosion-proof inverters can be flexibly changed according to customer requirements. If you have special needs, please contact our company R & D department. The company only provides explosion-proof inverter inner cores, and does not design and produce explosion-proof enclosures.
1140V Voltage Class
|
|
|
|
V5−H−BT Appearance, Installation Size and Approximate Weight
Voltage |
Power(kW) |
Appearance, Installation Size(mm) |
Weight (kg) |
||||||
W |
H |
D |
W1 |
H1 |
D1 |
d |
|||
1140V |
37~132 |
590 |
1280 |
365 |
506 |
1255 |
271 |
14 |
80 |
160~250 |
800 |
1700 |
450 |
716 |
1669 |
351 |
14 |
130 |
|
280~500 |
1000 |
2552 |
800 |
880 |
2200 |
700 |
20 |
220 |
|
560~710 |
1200 |
2552 |
800 |
1080 |
2200 |
700 |
20 |
250 |
Notes:
♦ For the 1140V series inverter, the air-cooled inverter is a standard product, and the explosion-proof inverter needs to be manufactured at client’s requirements. Explosion-proof inverter’s installation size, can be customized at client’s requirements. If you have any special requirements, please contact research and development department in company.
♦ Company only provide explosion-proof inverter and inner core, not produce explosion-proof enclosure.
Applications
|
|
|
|
|
|
|
|
|
Industrial Control Inverters Representative Industry
An ac drive is a device that is used to control the speed of an electric motor. The use of VFDs, also known as variable speed drives (VSD), is becoming common in operating motors used in heating, ventilating, and air conditioning (HVAC) systems within buildings. As an advanced Inverter Drive Manufacturer, The Middle Voltage High-performance Universal Inverter of Shenzhen V&T Technologies Co.,Ltd. are widely used in Fan, Pump, Oilfield,Inner Parts for Safety and Explosion-proof Machine ,Mining Winch,Coal Mine,Hoist,Municipal Engineering, Rubber and Plastics Machine.
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Categories
Copyright © 2024 Shenzhen V&T Technologies Co.,Ltd.. All Rights Reserved. Power by
IPv6 network supported